Loading…
Measured on Mini Quad Test Bench load-cell stand, 6S Venom 60A bench power supply + 2 x 2F caps, XRotor 40A ESC, 4ms datalogger. Tested KV 1746 vs 1800kv rating.
Static bench, 6S (~25.2V no-load).
| Throttle | Thrust (g) | Current (A) | Voltage (V) | RPM |
|---|---|---|---|---|
| 0% | 61 | 1.8 | 24.3 | 6,3241.40 g/W |
| 25% | 216 | 3.3 | 24.2 | 12,1092.69 g/W |
| 50% | 637 | 9.1 | 24.1 | 20,7662.91 g/W |
| 75% | 1193 | 20.3 | 23.9 | 28,6712.47 g/W |
| 100% | 1790 | 36.1 | 22.8 | 35,4152.18 g/W |
Measured data· verified 19 Sept 2026·source
Static bench, 6S (~25.2V no-load).
| Throttle | Thrust (g) | Current (A) | Voltage (V) | RPM |
|---|---|---|---|---|
| 0% | 62 | 1.7 | 24.3 | 6,3821.50 g/W |
| 25% | 225 | 3.4 | 24.2 | 12,1242.77 g/W |
| 50% | 676 | 9.5 | 24.1 | 20,5122.94 g/W |
| 75% | 1300 | 22.6 | 23.8 | 28,0042.42 g/W |
| 100% | 1931 | 42.1 | 23.6 | 33,3041.94 g/W |
Measured data· verified 19 Sept 2026·source
Static bench, 6S (~25.2V no-load).
| Throttle | Thrust (g) | Current (A) | Voltage (V) | RPM |
|---|---|---|---|---|
| 0% | 77 | 1.8 | 24.3 | 6,2421.79 g/W |
| 25% | 269 | 3.8 | 24.3 | 11,7502.92 g/W |
| 50% | 762 | 11.4 | 24.2 | 19,5252.77 g/W |
| 75% | 1405 | 26.7 | 23.7 | 26,4562.22 g/W |
| 100% | 1973 | 46.3 | 23.1 | 31,2581.84 g/W |
Measured data· verified 19 Sept 2026·source